Ferroli domina c24 e service manualDomina

The appliance offers the user compact dimensions, robust construction and simple. DOMINA C 20 N. DOMINA C 24 N. DOMINA C 28 N. DOMINA F 24 N. - Bithermic copper exchanger. - Combined control.

• • Wall-Mounting Gas Boiler • Airtight Chamber, for Hot Water and Heating TECHNICAL MANUAL EDITION 09•2002 Supplied By www.heating spares.co Tel. 0161 620 6677.

• DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E 1. Technical characteristics and data.3 1.1 Introduction..3 1.2 Dimensions and connections. 4 1.3 General view and main components.8 1.4 Technical data table.. • Certification The CE marking demonstrates that Ferroli gas units conform to the requirements contained in the applicable European directives. In particular, this unit complies with the following EU directives: •. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E 1.2 Dimensions and connections Domina F 24 E version Top view System delivery Tap water outlet Gas inlet Tap water inlet Bottom view System return Version - 09.2002 Supplied By www.heating spares.co Tel.

• DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E Ferella F 24 MEL version & Milos Air Compact E version Top view System delivery Tap water outlet Gas inlet Tap water inlet Bottom view System return Version - 09.2002 Supplied By www.heating spares.co Tel. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E Domina F 30 E version Top view System delivery Tap water outlet Gas inlet Tap water inlet Bottom view System return Version - 09.2002 Supplied By www.heating spares.co Tel. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E Ferella F 30 MEL version Top view System delivery Tap water outlet Gas inlet Tap water inlet System return Bottom view Version - 09.2002 Supplied By www.heating spares.co Tel. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E 1.3 General view and main components F 24 E/MEL version Airtight chamber Gas inlet Tap water outlet Tap water inlet System delivery System return Safety valve Combustion chamber Burner unit.

• DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E F 30 E/MEL version Airtight chamber Gas inlet Tap water outlet Tap water inlet System delivery System return Safety valve Combustion chamber Burner unit Main nozzle Burner Combustion chamber insulation. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E 1.4 Technical data table Version - 09.2002 Supplied By www.heating spares.co Tel.

0161 620 6677. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E 2. PRODUCT FRAMEWORK AND INTERNAL COMPONENTS 2.1 Hydraulic circuit – heating Hydraulic diagram for heating When there is a call for heat, the room thermostat or control system make the burners ignite and the circulation pump come into operation. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E Circulator (230v/50Hz) Located on the heating circuit return, it is connected directly to the exchanger via special forks and connected to the system via a threaded brass section. It has three delivery/head levels (see diagram). State of decay cheats xbox. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E Expansion tank It is connected to the pump casing via a pipe with a fork connection.

On the 24kW version, it is located above the pump, while on the 30kW version it is located behind the exchanger, inside the frame. The expansion tank contains a diaphragm in contact, on one side, with the system water and, on the other side, with the air under pressure (pre-loaded to 1 bar) inside the tank. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E Hydraulic unit This is a single piece of brass to which the exchanger delivery is connected for ease of access. It accommodates a number of safety and adjustment components. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E 2.2 Hydraulic circuit – tap water Hydraulic diagram for tap water Airtight chamber Gas inlet Tap water outlet Tap water inlet System delivery System return Safety valve Burner unit Heat exchanger. • DOMINA F 24 - 30 E FERELLA F 24 - 30 MEL MILOS AIR COMPACT E Flow meter Located at the cold water inlet, its task is to provide the card with a signal at a frequency (7 Hz per litre) in direct proportion to the tap-water flow rate. It is composed of a body (stator) and a rotor inside it.